Tree Canopy


Tree Protection fencing is supposed to be high visibility plastic construction fencing or other approved equivalent restraining material 5 ft in height to be clearly visible and separate from silt fencing. A barrier like the above photo protects the tree canopy and ensures silt remains on the property and out of the waterways.
TCCA - Tree Canopy Credit Area
Chapter 10 Part 1 of the Land Development Code (LDC): Tree Canopy
Every development that has a "Tree Preservation / Protection Area" (a.k.a. TCPA - TREE CANOPY PROTECTION AREA) is supposed to have an 8X10 weatherproof version of this sign every 50 feet creating a "Tree Preservation Protection Fence." The fence is supposed to be "high visibility plastic construction fencing or other approved equivalent restraining material...supported by steel pipe, tee posts, U posts or 2” x 4” timber posts that are a minimum of 5 ½ feet in height..."
10D-1, Page 780 of the LDC states: "Prior to any site disturbance permit being issued and Prior to any clearing, grading or the issuance of a site disturbance permit, a site inspection shall be conducted by PDS staff to ensure proper placement of required tree protection fencing in accordance with the approved Tree Preservation Plan."
10D-2, Page 781 of the LDC states: "Tree protection fencing shall be erected adjacent to all TCPAs prior to Site Disturbance Approval to protect the existing tree stands and their root systems. The fencing shall be located at least three (3) feet from the outside edge of the tree canopy and shall remain in place until all construction is completed. 4. No parking, material storage or construction activities are permitted within the TCPAs."
"During all construction activity (includes clearing, grading, building construction and VUA construction) a copy of the approved tree preservation plan shall be on site. "
Chapter 4 Part 6 of the LDC: Development On Sites with Environmental Constraints
4.6.4.B Compliance with Applicable Regulations - Standards for Protection During Construction
Site disturbance limits shall be designated in the field prior to commencement of excavation, grading, or construction with construction barrier fencing or other methods approved by DPDS. For trees and clumps of trees to be preserved within the site disturbance limit, tree protection specifications as required in Chapter 10 Part 1, “Tree Canopy,” shall be followed.
Every landscaping plan includes the LDC language and an example of the weather proof signage.




Lost Canopy